Place of Origin:
China
Brand Name:
SOUNDON
Certification:
UN38.3,UL ,CB ROSH
Model Number:
SD-EV-64-400
64V Lifepo4 Electric Sweep Lithium Polymer Battery Pack With Charge And Case
Specifications:
Battery Cell Type | LIFEPO4 | Rated Voltage | 3.2V | Rated Capacity | 20Ah |
Battery pack Voltage | 64V | Voltage Range | 60-73V | Rated Voltage | 400Ah |
Battery pack Energy
|
25℃ | 25.6KWh (100% DOD @ 1C rate) | |||
- 20℃ | 15.36KWh(100% DOD @ 1C rate) | ||||
Standard Charge/Discharge | 40A/60A | Fast Charge/Discharge | 100 A/250A | ||
Max Charge/Discharge Current | 150A/250A(5Seconds) | ||||
Charging Environment | 0℃~45℃,≤90%RH | Discharge Environment | -20℃~60℃,≤90%RH | ||
Working Temperature | Charging | 5℃~40℃ | Discharging | -30℃~65℃ | |
Self Discharge | 25°C,Every Month ≤0.9% | Storage Temperature | 0~40℃ |
the BMS Specificaiton :
The BMS use distributed two level management systems. Composed of one BCU and several BMU, LCD, CS and also cables
Item | Specification | Remark |
Voltage acquisition range |
0~5V | |
Voltage acquisition |
≤±0.5% | |
Sum Voltage | ≤0.2% | |
Current acquisition |
≤±1%FSR |
300A Current Sensor |
estimated SOC deviation SOC |
≤5% | |
Temperature acquisition |
≤±1℃ | -30~75℃ |
Temperature acquisition range |
-40~125℃ | |
Balancing current |
≤500mA ≤500mA (normal temperature) |
2 route balancing
|
BMU work power BMU |
≤3W | |
BCU work power BCU |
≤2.8W | |
Operation input voltage
|
DC 12/24V | |
System work temperature range
|
-30~75℃ | |
System storage temperature range |
-40~85℃ | |
Charging control |
CAN Communication, active/passive circuit output |
according to actual situation |
Discharging control
|
CAN Communication , active/passive circuit output |
according to actual situation |
BMS Funtion :
1) SOC Calculating:Use Vmin EKF algorithm, dynamically estimate the battery pack SOC
2) Current detection: Via the Hall current sensor, real-time detection of the current charge and discharge circuit
3) Communication function: 3-Way Can interface outside, can communicate with BMU, vehicle controller, charger etc to collect interactive voltage, temperature,error code,control instructions and other information.
4) Alarm and Protection: When overcharge, over discharge happened, BCU can implement appropriate alarm and protection under error condition, and display on LCD screen.
5)System Expansion: BCU supports multiple active/passive node output, it can achieve ensuring the effective strength of electrical isolation, security controls via CAN communication and relay control and management levels, to meet customer diverse requirements.
6)Data storage:Support 8G data storage, can record power battery pack long-time running entire performance parameters and battery pack adjusting and errors.
7)System self-test
8) Remote management
Safety test:
Item | Test name | Result |
1 |
High humidity& high temperature |
No distortion, no explosion and no fire. |
2 | Vibration | No distortion, no explosion, no fire, no smoke and no leaking |
3 | Mechanical shock | No fire. No explosion. No leakage. |
4 | Short circuit | No explosion, no fire. |
5 | Thermal abuse (cell) | No fire, no explosion. |
6 | Crushing of cells | No fire, no explosion. |
Send your inquiry directly to us